Skip to main content
TDEC

Digital I/O Module (DI / DO)

  • 20 single-ended digital inputs supporting ground/open, power/open and power/ground types
  • 28 single-ended isolated digital outputs with drive current of at least 20mA
  • Input type and output supply configured per 4-channel group, 12V / 28V selectable
  • Programmable auto-forwarding between DIO channels — no host intervention required
  • Two-bit IO status read-back distinguishing fault / ground-off / power-off / open circuit
  • DIO data stored on the module with automatic capacity management, and forwarded to the zero-slot host
  • Isolated output design, built on 100% domestic chips

Need selection advice or an on-site demo? Use the buttons above and our engineers will reach out shortly.

Specifications

ItemValueNote
Digital Input (DI)
Channel Configuration20 single-ended
Input TypesGround/open, power/open, power/groundInput type configured per 4-channel group first
Digital Output (DO)
Channel Configuration28 single-ended (isolated)
Output TypesGround/open, power/open, power/ground
Output Supply12V / 28V configurableSupply configured per 4-channel group first
level steps 5 / 10 / 15 / 28V
Drive Current≥20mA
Data Handling & Storage
Parameter SetupDIO parameters set per group of four channels
Auto-ForwardingProgrammable auto-forwarding between DIO channels
IO Status CodeBA=00 fault, 01 ground-off, 10 power-off, 11 open circuit
On-Board StorageDIO data stored on the module, capacity managed automatically with the oldest data discarded when full
Host ForwardingDIO data forwarded to the zero-slot module (host)
Parameter PersistenceSaved automatically, reloaded at power-on
Platform Common Characteristics
MountingFront-inserted card, quickly swappable
Standalone UseDetachable from the chassis for standalone use over gigabit Ethernet
Backplane CommunicationPower, command, synchronization and status signals unified over the backplane
Localization Rate100%
Component Temperature Grade-40℃ ~ 85℃ wide temperature

FAQ

How should the two-bit IO status code be read?
The module reports each IO channel with two bits (BA): 00 means fault, 01 ground-off, 10 power-off and 11 open circuit. Unlike a plain high/low reading, this code separates a broken wire (open circuit) from a line pulled to ground or to supply, so wiring and unit-under-test faults can be located on the spot during integration testing.